膜吸收CO2过程中甘氨酸钾吸收剂对聚偏氟乙烯中空纤维膜的浸润研究

王永飞;崔丽云;丁忠伟;刘丽英

北京化工大学学报(自然科学版) ›› 2015, Vol. 42 ›› Issue (3) : 23-27.

PDF(1647 KB)
欢迎访问北京化工大学学报(自然科学版),今天是 2025年7月22日 星期二
Email Alert  RSS
PDF(1647 KB)
北京化工大学学报(自然科学版) ›› 2015, Vol. 42 ›› Issue (3) : 23-27.
化学与化学工程

膜吸收CO2过程中甘氨酸钾吸收剂对聚偏氟乙烯中空纤维膜的浸润研究

  • 王永飞;崔丽云;丁忠伟;刘丽英
作者信息 +

Wetting of polyvinylidene fluoride hollow fiber membranes during the absorption of CO2 by potassium glycinate solution

  • WANG YongFei;CUI LiYun;DING ZhongWei;LIU LiYing
Author information +
文章历史 +

摘要

研究了聚偏氟乙烯(PVDF)中空纤维膜接触器吸收CO2过程中,吸收剂甘氨酸钾(PG)溶液对微孔膜的浸润随操作时间的变化,分别考察了溶液浓度、温度、吸收时间等条件对膜浸润的影响。结果表明:PG溶液浓度越高,膜浸润程度越低;温度越高,膜浸润程度越大;膜浸润程度随着吸收时间的延长而不断增大。同时还研究了膜浸润对总吸收传质系数的影响,极小程度的膜浸润导致传质系数大幅下降,在0.5mol/L,308.15 K条件下实验运行40h后膜孔平均浸润率达到0.181,总传质系数下降幅度达88.33%。

Abstract

Studies of wetting during the absorption of CO2 by potassium glycinate (PG) aqueous solution using hydrophobic polyvinylidene fluoride (PVDF) hollow fiber membrane contactors have been carried out under different operating conditions of concentration, temperature of absorbent and time. The results showed that the lower the concentration of PG and the higher the temperature of the absorbent, the higher the degree of wetting. The degree of membrane wetting increased after prolonged running times. The impact of membrane wetting on the overall mass transfer coefficient was also studied. The mass transfer coefficient increased significantly for only a tiny extent of membrane wetting. For a PG concentration of 0.5 mol/L and a temperature of 308.15 K, after running for 40 hours the average wetting ratio reached 0.181 with an 88.33% decrease in total mass transfer coefficient.

引用本文

导出引用
王永飞;崔丽云;丁忠伟;刘丽英. 膜吸收CO2过程中甘氨酸钾吸收剂对聚偏氟乙烯中空纤维膜的浸润研究[J]. 北京化工大学学报(自然科学版), 2015, 42(3): 23-27
WANG YongFei;CUI LiYun;DING ZhongWei;LIU LiYing. Wetting of polyvinylidene fluoride hollow fiber membranes during the absorption of CO2 by potassium glycinate solution[J]. Journal of Beijing University of Chemical Technology, 2015, 42(3): 23-27

参考文献

[1]Zhang H Y, Wang R, Liang D T, et al. Theoretical and experimental studies of membrane wetting in the membrane gas-liquid contacting process for CO2 absorption [J]. Journal of Membrane Science, 2008, 308: 162-170.[2]Mosadegh-Sedghi S, Rodrigue D, Brisson J, et al. Wetting phenomenon in membrane contactors-Causes and Prevention[J]. Journal of Membrane Science, 2014, 452: 332-353. 
[3]Mansourizadeh A, Ismail A F. Hollow fiber gas-liquid membrane contactors for acid gas capture: A review
[J]. Journal of Hazardous Materials, 2009, 171: 38-53. 
[4]Goyal N, Suman S, Gupta S K. Mathematical modeling of CO2 separation from gaseous-mixture using a
hollow-fiber membrane module: Physical mechanism and influence of partical-wetting [J]. Journal of Membrane Science, 2015, 474: 64-82. 
[5]Boributh S, Jiraratananon R, Li K. Analytical solutions for membrane wetting calculations based on log-
normal and normal distribution functions for CO2 absorption by a hollow fiber membrane contactor[J]. Journal of Membrane Science, 2013, 429: 459-472. 
[6]Yan S P, Fang M X, Zhang W F, et al. Experimental study on the separation of CO2 from flue gas using
hollow fiber membrane contactors without wetting [J]. Fuel Processing Technology, 2007, 88: 501-511.
[7]崔丽云, 王宇, 丁忠伟, 等. 膜接触器吸收二氧化碳过程中的膜浸润研究[J]. 膜科学与技术, 2013, 34(4): 33-
38. 
Cui L Y, Wang Y, Ding Z W, et al. Study on the membrane wetting in the process of CO2 absorption by membrane
contactor[J]. Membrane Science and Technology, 2013, 34(4): 33-38. (in Chinese)
[8]Decoursey W J. Absorption with chemical reaction: Development of a new relation for the danckwerts model
[J]. Chemical Engineering Science, 1974, 29: 1867-1872. 
[9]Eslami S, Mousavi S M, Danesh S, et al. Modeling and simulation of CO2 removal from power plant flue gas
by PG solution in a hollow fiber membrane contactor [J]. Advances in Engineering Software, 2011, 42: 612-620. 
[10]Porugal A F, Derks P W J, Versteeg G F, et al. Characterization of potassium glycinate for carbon
dioxide absorption purposes [J]. Chem Eng Sci, 2007, 62: 6534-6547.